Siemens .NET Client Library for SIMATIC S7 Webserver API (ICSA-26-321-02)

Command
CYBERCOM
Region
Cyber
Category
Cyber threat
Source
CISA Cybersecurity Advisories
Cyber ThreatOfficial statement

At a glance

What
Cyber Threat
Who
CISA Cybersecurity Advisories
When
Nov 17, 2026 at 12:00 PM UTC

Statement from CISA Cybersecurity Advisories, November 17.

Summary

.NET Client Library for Simatic S7 Webserver API contains multiple vulnerabilities that could allow an attacker to obtain sensitive information or write arbitrary files outside the intended download directory. Siemens has released a new version for .NET Client Library for Simatic S7 Webserver API and recommends to update to the latest version.

The following versions of Siemens .NET Client Library for Simatic S7 Webserver API are affected:

.NET Client Library for Simatic S7 Webserver API vers:intdot/<3.3.61, vers:intdot/<3.3.62 (CVE-2026-85114, CVE-2026-85115)

CVSS

Vendor

Equipment v3 7.5

Siemens

.NET Client Library for Simatic S7 Webserver API

2 Vulnerabilities

Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal'), Generation of Error Message Containing Sensitive Information

Background

Critical Infrastructure Sectors: Critical Manufacturing

Countries/Areas Deployed: Worldwide

Company Headquarters Location: Germany

Vulnerabilities

Expand All +

CVE-2026-85114

Affected applications do not properly validate filenames received from remote servers during ticket downloads. This could allow an attacker who can manipulate the ticket response to write arbitrary files outside the intended download directory and, when overwriting is enabled, replace existing files accessible to the application.

Read More

1 Affected Product

.NET Client Library for Simatic S7 Webserver API < V3.3.61

Product Status: known_affected

Remediations

Vendor fix

Update to V3.3.61 or later version

Additional Metrics

Relevant CWE: CWE-22 Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')

CVSS Version

Base Score

Base Severity

Vector String

3.1

7.5

High

CVSS:3.1/av:N/ac:L/PR:N/ui:N/S:U/C:N/I:H/a:N

View CVE Details

CVE-2026-85115

Affected applications do not properly redact PLC restore passwords from HTTP error exception messages. This could allow an attacker with access to logs or other diagnostic output to obtain the plaintext restore password and potentially perform unauthorized operations on the PLC.

Read More

2 Affected Products

.NET Client Library for Simatic S7 Webserver API < V3.3.61

Product Status: known_affected

Remediations

.NET Client Library for Simatic S7 Webserver API < V3.3.62

Product Status: known_affected

Remediations

Vendor fix

Update to V3.3.62 or later version

Additional Metrics

Relevant CWE: CWE-209 Generation of Error Message Containing Sensitive Information

CVSS Version

Base Score

Base Severity

Vector String

3.1

5.5

Medium

CVSS:3.1/av:L/ac:L/PR:L/ui:N/S:U/C:H/I:N/a:N

View CVE Details

Acknowledgments

Siemens ProductCERT reported these vulnerabilities to CISA.

General Recommendations

As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms.

Additional Resources

Terms of Use

Recommended Practices

CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks.

When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.

CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.

CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.

Advisory Conversion Disclaimer

This ICSA is a verbatim republication of Siemens ProductCERT SSA-390352 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Siemens ProductCERT directly for any questions regarding this advisory.

Revision History

Initial Release Date: 2026-10-13

Date

Revision

Summary

2026-10-13

1

Publication Date

2026-11-10

2

Added researcher acknowledgement

2026-11-17

3

Initial CISA Republication of Siemens ProductCERT SSA-390352 advisory

Legal Notice and Terms of Use

Source: CISA Cybersecurity Advisories

Understanding Global Threats

Browse All Topics & Pages

Complete sitemap with all intelligence resources

View Sitemap →

Digital Security & Backup

Protect your data and maintain connectivity

Global Conflict Map

Live snapshot of conflict locations and tension zones worldwide.

Map data last updated: November 17, 2026

Related Alerts

Keep Exploring