Siemens Industrial Automation Software Products (ICSA-26-321-03)
- Command
- CYBERCOM
- Region
- Cyber
- Category
- Cyber threat
- Source
- CISA Cybersecurity Advisories
At a glance
- What
- Cyber Threat
- Who
- CISA Cybersecurity Advisories
- When
- Nov 17, 2026 at 12:00 PM UTC
Statement from CISA Cybersecurity Advisories, November 17.
Summary
On October 21, 2026, the Node.js project released security updates addressing a critical vulnerability in the Brotli decoder bundled with Node.js, commonly referred to as "Node2Shell" (tracked as CVE-2026-111497). The vulnerability is an out-of-bounds write that could allow a remote attacker to cause memory corruption and potentially execute arbitrary code. This advisory covers the status of impact of various Siemens products. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fixes and recommends specific mitigations for products where fixes are not or not yet available.
The following versions of Siemens Industrial Automation Software Products are affected:
COMOS Walkinside vers:all/* (CVE-2026-111497) gDAP (gPROMS Digital Application Platform) vers:all/* ()
Project Server Web Administration Tool vers:all/* (CVE-2026-111497)
SIMATIC Braumat vers:intdot/>=8.2.0.1|<8.2.0.5 (CVE-2026-111497)
SIMATIC Profiling Tool vers:all/* (CVE-2026-111497)
SIMATIC Sistar vers:intdot/>=8.2.0.1|<8.2.0.5 (CVE-2026-111497)
SIMATIC WinCC Companion vers:all/* (CVE-2026-111497)
SIMATIC WinCC Oa V3.20 vers:intdot/<3.20.17.1 (CVE-2026-111497)
SIMATIC WinCC Oa V3.21 vers:all/* (CVE-2026-111497)
SIMATIC WinCC Runtime Professional vers:all/* (CVE-2026-111497)
SIMATIC WinCC Unified for Industrial Edge vers:all/* (CVE-2026-111497)
SIMATIC WinCC Unified PC Runtime vers:all/* (CVE-2026-111497)
SIMATIC WinCC Unified SIQENCE vers:all/* (CVE-2026-111497)
SIMATIC WinCC V7/V8 vers:all/* (CVE-2026-111497)
TIA Administrator vers:all/* (CVE-2026-111497)
User Management Component (UMC) vers:all/* (CVE-2026-111497)
CVSS
Vendor
Equipment v3 9.8
Siemens
COMOS Walkinside
1 Vulnerability
Out-of-bounds Write
Background
Critical Infrastructure Sectors: Critical Manufacturing, Food and Agriculture, Energy
Countries/Areas Deployed: Worldwide
Company Headquarters Location: Germany
Vulnerabilities
CVE-2026-111497
A buffer overflow vulnerability in the Brotli decoder (c/dec/decode.c) in Google Brotli versions 1.0.3 through 1.2.0 on all platforms allows a remote unauthenticated attacker to corrupt adjacent decoder state memory, disclose sensitive memory contents, cause a denial of service, or potentially execute arbitrary code using a crafted Brotli-compressed stream. Users need to update any Brotli libraries or binaries between 1.0.3 through 1.2.0 to the latest available version: 1.0.10 or 1.1.1 or 1.2.1.
Read More
15 Affected Products
COMOS Walkinside
Product Status: known_affected, known_not_affected
Remediations
Mitigation
Temporarily disable Brotli compression and decompression at the application or proxy layer if it is not strictly required
None available
Currently no fix is available
SIMATIC WinCC Runtime Professional
Product Status: known_affected, known_not_affected
Remediations
Mitigation
Temporarily disable Brotli compression and decompression at the application or proxy layer if it is not strictly required
None available
Currently no fix is available
SIMATIC WinCC Unified for Industrial Edge
Product Status: known_affected, known_not_affected
Remediations
Mitigation
Temporarily disable Brotli compression and decompression at the application or proxy layer if it is not strictly required
None available
Currently no fix is available
SIMATIC WinCC Unified PC Runtime
Product Status: known_affected, known_not_affected
Remediations
Mitigation
Temporarily disable Brotli compression and decompression at the application or proxy layer if it is not strictly required
None available
Currently no fix is available
SIMATIC WinCC Unified SIQENCE
Product Status: known_affected, known_not_affected
Remediations
Mitigation
Temporarily disable Brotli compression and decompression at the application or proxy layer if it is not strictly required
None available
Currently no fix is available
SIMATIC WinCC V7/V8
Product Status: known_affected, known_not_affected
Remediations
Mitigation
Temporarily disable Brotli compression and decompression at the application or proxy layer if it is not strictly required
None available
Currently no fix is available
TIA Administrator
Product Status: known_affected, known_not_affected
Remediations
Mitigation
Temporarily disable Brotli compression and decompression at the application or proxy layer if it is not strictly required. If UMC authentication is enabled, block requests that use Brotli compression: in IIS Manager, select the Default Web Site, open "Request Filtering" > "Rules", click "Add Filtering Rule", enter Name "CVE-2026-111497", Scan Headers "Content-Encoding" and Deny Strings "br", then click OK.
None available
Currently no fix is available
User Management Component (UMC)
Product Status: known_affected, known_not_affected
Remediations
Mitigation
Temporarily disable Brotli compression and decompression at the application or proxy layer if it is not strictly required. In IIS Manager, select the Default Web Site, open "Request Filtering" > "Rules", click "Add Filtering Rule", enter Name "CVE-2026-111497", Scan Headers "Content-Encoding" and Deny Strings "br", then click OK.
None available
Currently no fix is available
Project Server Web Administration Tool
Product Status: known_affected, known_not_affected
Remediations
Mitigation
Temporarily disable Brotli compression and decompression at the application or proxy layer if it is not strictly required
None available
Currently no fix is available
SIMATIC Braumat >= V8.2 Update 1 < V8.2 Update 5
Product Status: known_affected, known_not_affected
Remediations
Mitigation
Temporarily disable Brotli compression and decompression at the application or proxy layer if it is not strictly required
Vendor fix
Update to V8.2 Update 5 or later version
SIMATIC Profiling Tool
Product Status: known_affected, known_not_affected
Remediations
Mitigation
Temporarily disable Brotli compression and decompression at the application or proxy layer if it is not strictly required
No fix planned
Currently no fix is planned
SIMATIC Sistar >= V8.2 Update 1 < V8.2 Update 5
Product Status: known_affected, known_not_affected
Remediations
Mitigation
Temporarily disable Brotli compression and decompression at the application or proxy layer if it is not strictly required
Vendor fix
Update to V8.2 Update 5 or later version
SIMATIC WinCC Companion
Product Status: known_affected, known_not_affected
Remediations
Mitigation
Temporarily disable Brotli compression and decompression at the application or proxy layer if it is not strictly required
None available
Currently no fix is available
SIMATIC WinCC Oa V3.20 < V3.20 P17.1
Product Status: known_affected, known_not_affected
Remediations
Vendor fix
Update to V3.20 P17.1 or later version
SIMATIC WinCC Oa V3.21
Product Status: known_affected, known_not_affected
Remediations
Mitigation
Temporarily disable Brotli compression and decompression at the application or proxy layer if it is not strictly required
None available
Currently no fix is available
Additional Metrics
Relevant CWE: CWE-787 Out-of-bounds Write
CVSS Version
Base Score
Base Severity
Vector String
3.1
9.8
Critical
CVSS:3.1/av:N/ac:L/PR:N/ui:N/S:U/C:H/I:H/a:H
View CVE Details
Acknowledgments
Siemens ProductCERT reported this vulnerability to CISA.
General Recommendations
As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms.
Additional Resources
Terms of Use
Recommended Practices
CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks.
When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.
CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.
CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.
Advisory Conversion Disclaimer
This ICSA is a verbatim republication of Siemens ProductCERT SSA-242944 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Siemens ProductCERT directly for any questions regarding this advisory.
Revision History
Initial Release Date: 2026-11-10
Date
Revision
Summary
2026-11-10
1
Publication Date
2026-11-17
2
Initial CISA Republication of Siemens ProductCERT SSA-242944 advisory
Legal Notice and Terms of Use
Source: CISA Cybersecurity Advisories