Statement from CISA Cybersecurity Advisories, November 17.
Summary
Mendix Studio Pro contains multiple vulnerabilities in the MCP Server, that could allow an attacker with network access to interact with the server remotely or trick a user's browser into sending unauthorized requests, potentially leading to unauthorized data access, tool execution, or system compromise. Siemens has released new versions for the affected products and recommends to update to the latest versions.
The following versions of Siemens Mendix Studio Pro are affected:
Mendix Studio Pro 11 vers:intdot/>=11.15.0|<11.16.0 (CVE-2026-112136, CVE-2026-112137)
Mendix Studio Pro 11.12 vers:intdot/>=11.12.6|<11.12.7 (CVE-2026-112136, CVE-2026-112137)
CVSS
Vendor
Equipment v3 8.8
Siemens
Mendix Studio Pro 11
2 Vulnerabilities
Binding to an Unrestricted IP Address, Cross-Site Request Forgery (CSRF)
Background
Critical Infrastructure Sectors: Critical Manufacturing, Energy
Countries/Areas Deployed: Worldwide
Company Headquarters Location: Germany
Vulnerabilities
Expand All +
CVE-2026-112136
The affected products MCP Server does not properly restrict its HTTP listener to the loopback interface, leaving it potentially exposed to remote systems. This could allow an attacker with network access to interact with the MCP Server remotely.
Read More
2 Affected Products
Mendix Studio Pro 11 >= V11.15.0 < V11.16.0
Product Status: known_affected
Remediations
Mitigation
Maintain strict inbound firewall policies (such as Windows Defender Firewall) blocking external traffic on port 7782. This is already the case by default on standard Windows installations. If remote access is required, restrict traffic via a secure, authenticated channel (e.g., a VPN or SSH tunnel) rather than opening direct inbound firewall rules.
Vendor fix
Update to V11.16.0 or later version
Mendix Studio Pro 11.12 >= V11.12.6 < V11.12.7
Product Status: known_affected
Remediations
Mitigation
Maintain strict inbound firewall policies (such as Windows Defender Firewall) blocking external traffic on port 7782. This is already the case by default on standard Windows installations. If remote access is required, restrict traffic via a secure, authenticated channel (e.g., a VPN or SSH tunnel) rather than opening direct inbound firewall rules.
Vendor fix
Update to V11.12.7 or later version
Additional Metrics
Relevant CWE: CWE-1327 Binding to an Unrestricted IP Address
CVSS Version
Base Score
Base Severity
Vector String
3.1
8.8
High
CVSS:3.1/av:N/ac:L/PR:N/ui:R/S:U/C:H/I:H/a:H
View CVE Details
CVE-2026-112137
The affected products MCP Server does not properly validate Content-Type and Origin headers on incoming HTTP requests, leaving it vulnerable to Cross-Site Request Forgery (CSRF). This could allow a malicious web page to trick a user's browser into sending unauthorized requests and executing unintended actions on the local MCP Server.
Read More
4 Affected Products
Mendix Studio Pro 11 >= V11.15.0 < V11.16.0
Product Status: known_affected
Remediations
Mitigation
Utilize modern Chromium- or WebKit-based browsers with Private Network Access protections enabled, or use browser extensions (such as uBlock Origin or NoScript) to block external websites from issuing fetch requests to localhost (127.0.0.1).
Vendor fix
Update to V11.16.0 or later version
Mendix Studio Pro 11.12 >= V11.12.6 < V11.12.7
Product Status: known_affected
Remediations
Mitigation
Utilize modern Chromium- or WebKit-based browsers with Private Network Access protections enabled, or use browser extensions (such as uBlock Origin or NoScript) to block external websites from issuing fetch requests to localhost (127.0.0.1).
Vendor fix
Update to V11.12.7 or later version
Mendix Studio Pro 11 >= V11.15.0 < V11.16.0
Product Status: known_affected
Remediations
Mitigation
Utilize modern Chromium- or WebKit-based browsers with Private Network Access protections enabled, or use browser extensions (such as uBlock Origin or NoScript) to block external websites from issuing fetch requests to localhost (127.0.0.1).
Vendor fix
Update to V11.16.0 or later version
Mendix Studio Pro 11.12 >= V11.12.6 < V11.12.7
Product Status: known_affected
Remediations
Mitigation
Utilize modern Chromium- or WebKit-based browsers with Private Network Access protections enabled, or use browser extensions (such as uBlock Origin or NoScript) to block external websites from issuing fetch requests to localhost (127.0.0.1).
Vendor fix
Update to V11.12.7 or later version
Additional Metrics
Relevant CWE: CWE-352 Cross-Site Request Forgery (CSRF)
CVSS Version
Base Score
Base Severity
Vector String
3.1
5.4
Medium
CVSS:3.1/av:N/ac:L/PR:N/ui:R/S:U/C:N/I:L/a:L
View CVE Details
Acknowledgments
Siemens ProductCERT reported these vulnerabilities to CISA.
General Recommendations
As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms.
Additional Resources
Terms of Use
Recommended Practices
CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks.
When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.
CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.
CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.
Advisory Conversion Disclaimer
This ICSA is a verbatim republication of Siemens ProductCERT SSA-710379 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Siemens ProductCERT directly for any questions regarding this advisory.
Revision History
Initial Release Date: 2026-11-10
Date
Revision
Summary
2026-11-10
1
Publication Date
2026-11-16
2
Mapped the advisory to Mendix products to be present on the Mendix Atom Feed
2026-11-17
3
Initial CISA Republication of Siemens ProductCERT SSA-710379 advisory
Legal Notice and Terms of Use
Source: CISA Cybersecurity Advisories