Siemens Mendix Studio Pro (ICSA-26-321-05)

Command
CYBERCOM
Region
Cyber
Category
Cyber threat
Source
CISA Cybersecurity Advisories
Cyber ThreatOfficial statement

At a glance

What
Cyber Threat
Who
CISA Cybersecurity Advisories
When
Nov 17, 2026 at 12:00 PM UTC

Statement from CISA Cybersecurity Advisories, November 17.

Summary

Mendix Studio Pro contains multiple vulnerabilities in the MCP Server, that could allow an attacker with network access to interact with the server remotely or trick a user's browser into sending unauthorized requests, potentially leading to unauthorized data access, tool execution, or system compromise. Siemens has released new versions for the affected products and recommends to update to the latest versions.

The following versions of Siemens Mendix Studio Pro are affected:

Mendix Studio Pro 11 vers:intdot/>=11.15.0|<11.16.0 (CVE-2026-112136, CVE-2026-112137)

Mendix Studio Pro 11.12 vers:intdot/>=11.12.6|<11.12.7 (CVE-2026-112136, CVE-2026-112137)

CVSS

Vendor

Equipment v3 8.8

Siemens

Mendix Studio Pro 11

2 Vulnerabilities

Binding to an Unrestricted IP Address, Cross-Site Request Forgery (CSRF)

Background

Critical Infrastructure Sectors: Critical Manufacturing, Energy

Countries/Areas Deployed: Worldwide

Company Headquarters Location: Germany

Vulnerabilities

Expand All +

CVE-2026-112136

The affected products MCP Server does not properly restrict its HTTP listener to the loopback interface, leaving it potentially exposed to remote systems. This could allow an attacker with network access to interact with the MCP Server remotely.

Read More

2 Affected Products

Mendix Studio Pro 11 >= V11.15.0 < V11.16.0

Product Status: known_affected

Remediations

Mitigation

Maintain strict inbound firewall policies (such as Windows Defender Firewall) blocking external traffic on port 7782. This is already the case by default on standard Windows installations. If remote access is required, restrict traffic via a secure, authenticated channel (e.g., a VPN or SSH tunnel) rather than opening direct inbound firewall rules.

Vendor fix

Update to V11.16.0 or later version

Mendix Studio Pro 11.12 >= V11.12.6 < V11.12.7

Product Status: known_affected

Remediations

Mitigation

Maintain strict inbound firewall policies (such as Windows Defender Firewall) blocking external traffic on port 7782. This is already the case by default on standard Windows installations. If remote access is required, restrict traffic via a secure, authenticated channel (e.g., a VPN or SSH tunnel) rather than opening direct inbound firewall rules.

Vendor fix

Update to V11.12.7 or later version

Additional Metrics

Relevant CWE: CWE-1327 Binding to an Unrestricted IP Address

CVSS Version

Base Score

Base Severity

Vector String

3.1

8.8

High

CVSS:3.1/av:N/ac:L/PR:N/ui:R/S:U/C:H/I:H/a:H

View CVE Details

CVE-2026-112137

The affected products MCP Server does not properly validate Content-Type and Origin headers on incoming HTTP requests, leaving it vulnerable to Cross-Site Request Forgery (CSRF). This could allow a malicious web page to trick a user's browser into sending unauthorized requests and executing unintended actions on the local MCP Server.

Read More

4 Affected Products

Mendix Studio Pro 11 >= V11.15.0 < V11.16.0

Product Status: known_affected

Remediations

Mitigation

Utilize modern Chromium- or WebKit-based browsers with Private Network Access protections enabled, or use browser extensions (such as uBlock Origin or NoScript) to block external websites from issuing fetch requests to localhost (127.0.0.1).

Vendor fix

Update to V11.16.0 or later version

Mendix Studio Pro 11.12 >= V11.12.6 < V11.12.7

Product Status: known_affected

Remediations

Mitigation

Utilize modern Chromium- or WebKit-based browsers with Private Network Access protections enabled, or use browser extensions (such as uBlock Origin or NoScript) to block external websites from issuing fetch requests to localhost (127.0.0.1).

Vendor fix

Update to V11.12.7 or later version

Mendix Studio Pro 11 >= V11.15.0 < V11.16.0

Product Status: known_affected

Remediations

Mitigation

Utilize modern Chromium- or WebKit-based browsers with Private Network Access protections enabled, or use browser extensions (such as uBlock Origin or NoScript) to block external websites from issuing fetch requests to localhost (127.0.0.1).

Vendor fix

Update to V11.16.0 or later version

Mendix Studio Pro 11.12 >= V11.12.6 < V11.12.7

Product Status: known_affected

Remediations

Mitigation

Utilize modern Chromium- or WebKit-based browsers with Private Network Access protections enabled, or use browser extensions (such as uBlock Origin or NoScript) to block external websites from issuing fetch requests to localhost (127.0.0.1).

Vendor fix

Update to V11.12.7 or later version

Additional Metrics

Relevant CWE: CWE-352 Cross-Site Request Forgery (CSRF)

CVSS Version

Base Score

Base Severity

Vector String

3.1

5.4

Medium

CVSS:3.1/av:N/ac:L/PR:N/ui:R/S:U/C:N/I:L/a:L

View CVE Details

Acknowledgments

Siemens ProductCERT reported these vulnerabilities to CISA.

General Recommendations

As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms.

Additional Resources

Terms of Use

Recommended Practices

CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks.

When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.

CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.

CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.

Advisory Conversion Disclaimer

This ICSA is a verbatim republication of Siemens ProductCERT SSA-710379 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Siemens ProductCERT directly for any questions regarding this advisory.

Revision History

Initial Release Date: 2026-11-10

Date

Revision

Summary

2026-11-10

1

Publication Date

2026-11-16

2

Mapped the advisory to Mendix products to be present on the Mendix Atom Feed

2026-11-17

3

Initial CISA Republication of Siemens ProductCERT SSA-710379 advisory

Legal Notice and Terms of Use

Source: CISA Cybersecurity Advisories

Understanding Global Threats

Browse All Topics & Pages

Complete sitemap with all intelligence resources

View Sitemap →

Digital Security & Backup

Protect your data and maintain connectivity

Global Conflict Map

Live snapshot of conflict locations and tension zones worldwide.

Map data last updated: November 17, 2026

Related Alerts

Keep Exploring